This file lists some (currently available) parts of Spectrum Lab's configuration
structure which can be accessed by the command interpreter.
Note: To access the following configuration variables through the interpreter,
they must be prefixed with "cfg." or "config.".
-
Example:
-
print("FFT size=",cfg.FFTSize,"points")
Warning: Read/write access for most of these variables has never been tested,
especially not from external programs using the
message-based communication protocol ! If you
need to access more of these parameters through the interpreter (or modify
them from another program) and find that something doesn't work as it should,
let me know.
FFT properties for the FIRST SPECTRUM ANALYZER...
-
FFTSize
-
FFT input size (number of sample points in the time domain)
-
FFTAverage
-
FFT average count (was once used to suppress noise in spectrograms)
-
FFTInputDec
-
Decimation ratio for the FFT input samples. Increases frequency resolution
but decreases displayable bandwidth.
-
FFTCenterFreq
-
Center frequency for "complex frequency conversion with decimation" before
the FFT.
-
FFTWindowFunc
-
Windowing function for the
FFT. Implemented (so far) :
0 = RECTANGLE (which actually means "no windowing")
1 = HAMMING
2 = HANN (named after Julius von Hann, not "Hanning")
3 = GAUSS
-
4 = NUTTALL
5 = FLAT_TOP
Configuration for the FIRST SPECTRUM DISPLAY...
-
SpecFreqMin
-
min displayed frequency
-
SpecFreqMax
-
max displayed frequency
-
SpecFreqOffs
-
"any user-offset" for displayed frequency
-
SpecAmplMin
-
amplitude range, min
-
SpecAmplMax
-
amplitude range, max
-
SpecDbOffsExpr
-
an expression to calculate a user-defined "zero-decibel point". Periodically
evaluated.
-
SpecDispOrient
-
orientation of the spectrum display and waterfall (horz,vert)
-
SpecGraphArea
-
Size of the spectrum graph area in pixels (the rest is used for frequency scale and spectrogram)
-
SpecDispMirror
-
mirror for the frequency axis (USB, LSB)
-
SpecDispStyle
-
display style (WHERE and WHAT is displayed)
-
SpecDispMode
-
display mode (outdated)
-
SpecOptiAverag
-
flag for "optimum spectrum average"
-
SpectrumActive
-
flag to enable/disable the spectrum analyzer
-
SpecAmplGrid
-
flag to turn the "amplitude grid" on and off
-
SpecFreqGrid
-
flag to turn the "frequency grid" on and off
-
SpecFreqGridSt
-
style for displaying the "frequency grid" (dotted, solid)
-
SpecBkgndColor
-
background color for spectrum graph
-
SpecGridColor
-
grid color for spectrum graph
-
SpecGrPenColor
-
pen color for spectrum graph
Waterfall display control
-
Wat1ClContrast
-
"Color Contrast" for the first (=main) waterfall display
-
Wat1ClBrightns
-
"Color Brightness" for the first (=main) waterfall display
-
Wat1FreqGrid
-
flag to turn the waterfall's frequency grid on and off
-
Wat1GridColor
-
grid color for the waterfall
-
Wat1TextColor
-
text color for the waterfall
-
Wat1LabelTrans
-
transparency of labels on the waterfall
-
Wat1TimeGrid
-
flag to enable/disable the "time grid" on the waterfall
-
Wat1TimeLabel
-
flag to enable/disable the "time label" on the waterfall
-
Wat1ScrollTime
-
scroll interval of the waterfall, time in seconds
-
Wat1Scrolling
-
flag if scrolling or "radar-like" waterfall
-
Wat1SmoothScr
-
flag if smooth scrolling shall be attempted
-
Wat1LineWidth
-
single or double waterfall line width
-
TimeGridStyle
-
style of time grid (dotted or solid)
-
TimeGridSecnds
-
spacing of time grid (in seconds)
Other display colors
-
FrScaleBgColor
-
Background color for the frequency scale
-
FrScaleFgColor
-
Foreground color for the frequency scale
System settings... sample rate, audio source and destination
-
NominalAudioSR
-
nominal audio sample rate as integer value, usually 5512, 11025, 22050, or
44100.
-
SrCalibEnable
-
flag to enable the sample rate calibrator
-
SrCalibConnect
-
numeric code for a channel where the sample rate calibrator is connected
to
-
SrCalibMinAmpl
-
minimum amplitude for the sample rate calibrator. If signal is too weak,
no calibration takes place
-
SrCalibAverags
-
count of average values for the sample rate calibrator
-
SrCalibRefFreq
-
reference frequency for the sample rate calibrator
-
SrCalibBdwidth
-
"observation" bandwidth of the sample rate calibrator
-
SrCalibMaxOffs
-
maximum tolerable frequency offset for the sample rate calibrator
-
FoCalibEnable
-
flag to enable the sample rate calibrator
-
FoCalibConnect
-
numeric code for a channel where the frequency offset (F.O.) calibrator is
connected to
-
FoCalibMinAmpl
-
minimum amplitude for the F.O. calibrator. If signal is too weak, no calibration
takes place
-
FoCalibAverags
-
count of average values for the F.O. rate calibrator
-
FoCalibRefFreq
-
reference frequency for the F.O. calibrator
-
FoCalibBdwidth
-
"observation" bandwidth of the F.O. calibrator
-
FoCalibMaxOffs
-
maximum tolerable frequency offset for the F.O. calibrator
-
StereoProcess
-
flag if mono or stereo processing (at the moment)
-
ConsumeADfile
-
flag if a "file server" shall be used instead of an A/D converter
-
ConsADfilename
-
name of the file which replaces an A/D converter
-
ToStartADfile
-
command line for ADC file server
-
ToStopADfile
-
command line for ADC file server
-
ProduceDAfile
-
flag if a "file server" shall be used instead of a D/A converter
-
ProdDAfilename
-
name of the file which replaces a D/A converter
-
ToStartDAfile
-
command line for DAC file server
-
ToStopDAfile
-
command line for DAC file server
-
MaxSrvFilesz
-
max. size of the file sent to or received from analogue file server
-
SpectRefFile
-
name of a file with spectrum reference data
-
SpectRefEnable
-
flag if the spectrum reference curve shall be active or visible on the screen
-
SpectRefSubtr
-
flag if the values from the recference curve shall be ""subtracted"" from
the spectra
-
SpectRefColor
-
color used to draw the spectrum reference curve
-
WavePlayLoops
-
flag if wave file shall be played in an endless loop
-
WavePlayUpsamp
-
flag if wave file shall be played with "upsampling"
-
WavePlayDownsp
-
flag if wave file shall be played with "downsampling"
-
WavePlayAAlias
-
flag if wave file shall be played with "anti-aliasing" when "upsampling"
-
WavePlaySpeedP
-
(not used at the moment) Speed percentage when playing wave file
-
WaveSaveDowns
-
flag if wave files shall be saved (recorded) with downsampling
-
WaveSaveSRate
-
wanted sample rate for recording wave files
-
WaveSaveFormat
-
to be defined
-
WaveSaveInfos
-
to be defined
-
WaveSaveIQpair
-
to be defined
-
WaveSaveCtFreq
-
to be defined
-
WaveSaveMaxKb
-
to be defined
Test signal generator
-
ConnGenToInput
-
to be defined
-
ConnGenToOutput
-
to be defined
-
ConnSlider1To
-
defines to which parameter the "value slider" is connected
-
GenNoiseLevel
-
noise level of the test signal generator
-
GenNoiseEnable
-
flag to activate "noise" from the test signal generator
-
GenAModFrequ
-
amplitude modulator frequency of the test signal generator
-
GenAModFactor
-
amplitude modulation factor of the test signal generator
-
GenAModCarrier
-
carrier amplitude for the test signal generator's AM modulator
-
GenAModWavefrm
-
waveform for AM modulator
-
GenFModFrequ
-
freq-modulator signal frequency of the test signal generator
-
GenFModDeviatn
-
freq-modulator deviation of the test signal generator
-
GenFModWavefrm
-
waveform for FM modulator
-
Gen1.xyz
-
parameters for 1st test signal generator cell
-
Gen2.xyz
-
parameters for 2nd test signal generator cell
-
Gen2.xyz
-
parameters for 3rd test signal generator cell
Input, Output, Circuit Components
-
AdcInputActive
-
flag for activity of the analog input
-
DacOutputActive
-
flag for activity of the analog output
-
SignalGenActive
-
flag for activity of the signal generator
-
UsrFilterActive
-
flag for activity of the user programmable filter
-
UsrFilterBypass
-
flag to bypass the filter (feed-through for comparison)
-
AmplifierGain
-
gain for all amplifiers which are visible in the "circuit diagram".
This is an array with indices ranging from 0 to 7, e.g.
cfg.AmplifierGain[0] to cfg.AmplifierGain[7]:
0 = amplifier at the output of the FFT-based filter, LEFT channel
1 = amplifier at the output of the FFT-based filter, RIGHT channel
2 = amplifier at the output of digitmode modulator, LEFT channel
3 = amplifier at the output of digitmode modulator, RIGHT channel
4 = output of test signal generator, LEFT channel
5 = output of test signal generator, RIGHT channel
6 = cross-coupling amplifier, left to right channel (signed factor, not dB)
7 = cross-coupling amplifier, right to left channel (signed factor, not dB)
-
-
DSP Blackboxes in the circuit
window
-
Each of the four (?) "DSP Blackboxes" has an awful lot of properties and
parameters. At the moment, they are *not* accessable through the "cfg"-command,
but only direcly, using the blackbox command (just "blackbox", not
"cfg.blackbox") as explained in another
document.
-
Settings for "Periodic" and "Scheduled" actions (not only 'capture' !)
-
PeriodicStart
-
time-of-day when the periodic actions shall begin
-
PeriodicStop
-
time-of-day when the periodic actions shall stop
-
PeriodicIntrvl
-
interval of periodic actions
-
PeriodicEnable
-
flag to enable/disable periodic actions
-
PeriodicAction
-
a string of interpreter commands
-
ScheduleEnable
-
flag to enable/disable scheduled actions
Other function blocks
-
DigiTrmEnable
-
to be defined
-
DigiTrmCWIdent
-
to be defined
-
DCF77DecEnable
-
to be defined
-
DebugMetronome
-
to be defined
Screen Capture Options
-
Capt1Options
-
what shall be contained in a captured screen ?
-
Capt1Sequence
-
the "serial number" (file index) of the captured files as seen in the control dialog.
Note: The file index only comes into play when the capture-command is invoked without parameters.
-
Capt1FileName
-
the default capture file name if the "capture" command is executed without
parameters
-
CaptureAsJpeg
-
well..
-
JpegQuality
-
percentage, 0=min 100=max JPEG quality (but also maximum size)
-
-
-