Bernd Neubig's Cross Reference of MIL-STD vs. IEC Standards* - Issue March 26, 2002
Test Method general general crystals oscillators filters  
MIL-STD Method Cond. MIL Conditions IEC 60068-2- IEC 60122-1   (IEC 601178-1) MIL-PRF 3098 IEC 60679-1 MIL-PRF 55310 IEC 60368-1 IEC conditions
Electrical Characteristics           several   several      
Freq. Vs. Temp.       per spec   several   several      
Aging       30 days, spec temp, 1 hour stabilization    4.9.1    4.7.1 4.8.35.1   30 days@85°C or upper op. Temp. OCXO: @25°C
Life Test/ Extended aging 883 2005,6   125°C, powered, 1000h min.    4.9.2    4.7.2     1000h, 2000h, 8000h @85°C
Bake-in/Burn-in 202
883
108
1015
                 
Visual inspections           4,5   4,3  4.8.1   Enclosures as in IEC 60122-3 (xtal), 60679-3 (osc), 60368-3 (filters)
Phys. Dimensions 883 2016   per Spec   4,6          
Dielectric withstanding voltage 202 302                  
Insulation resistance 202 302                  
Electrostatic Discharge 883 3015 Class II 2kV to 4kV threshold              
Contact Resistance 202 307                  
Solderability 202
883
208
2022,2
 
Solder dip, Meniscograph
 -20 and -54 and -58 and  -69  4.8.3    4.6.3.1  4.8.53   Leads:Test Ta Meth.1 (235+-5)°C                 SMD: Test Td solder bath (235+-5)°C or Test Te (wetting balance)
883 2003   8h steam age, 95% coverage              
Resistance to Soldering Heat 202 210A C 260°C, 10sec, 25.4mm/sec -20  4.8.3    4.6.3.2  4.8.49   Leads: Test Tb Meth.1A (solder bath 5s),   SMD: Test Td (solder bath 10s, (260+-5)°C)
Moisture Resistance 202
810
106
507
                 
Sealing Test:                  Fine Leak 202         883 112     1014.8              A1 Mass Spectrometer                            1*10-8 He -17  4.8.2    4.6.2  4.8.2   Test  Qk
Sealing Test:               Gross Leak 202
883
112
1014
  30sec immersion -17  4.8.2    4.6.2  4.8.2   Test Qc
Robustness of terminations: Lead integrity 202
883
211
1005,6
 
Lead tension & bend stress
-21  4.8.1    4.6.1  4.8.52   Tests  Ua1,Ua2,Ub
Robustness of terminations: Lead Bend 883 2004 B1 1 bending cycle -21          
Robustness of terminations: Terminal Pull 883 2004 A 2 pd -21  4.8.1          
Immersion in cleaning solvents; Marking permanence 202
202
883
104
215
2015,8
 

Resistance to solvents, three 1min soaks
 -45 and -70  4.8.16    4.6.21  4.8.54   Test Xa method 1,                Test Xb (rubbing finger)  (for superficial marking only)
Flammability (external flame) 202 111A                  
Vibration Sinusoidal 202
202
810
201
204
514

B

10-2000Hz,1.5mm/15g, 3 planes
-6  4.8.7    4.6.7.1 and 4.6.7.2  4.8.39.1 and 4.8.39.2   Test Fc: 30min per axis, 10-55Hz 0.75mm; 55-2000Hz, 10g
Vibration Random 202 214     -36  4.8.7      4.8.39.3   Test Fdb: e.g.100Hz-2kHz, 0.04g²/Hz
Mechanical Shock 202
202
810
207
213
516

C

100g
-27  4.8.8    4.6.8  4.8.41   Test Ea: 3x per axes,100g, 6ms, halfsine
Mechanical Bump         -29  4.8.6    4.6.6     Test Eb: 4000 bumps per axes, 40g, 6ms
Constant Acceleration 202
883
212
2001
                 
Altitude (Barometric Pressure) 202
810
105
500
                 
Salt Spray 202
810
101
509
                 
Explosion 202
810
109
511
                 
Sand and Dust 202
810
110
510
                 
Fungus 810 508                  
Free Fall, Random Drop 202 203     -32  4.8.9         Test Ed proc.1:                         2 drops from 1m height
Particle Impact Noise Detection (PIND) 202
883
217
2020
                 
Dry heat         -2  4.8.11    4.6.14     Test Ba: 16 h at upper temp of climatic category
Damp heat, cyclic         -30  4.8.12    4.6.15     Test  Db var.1 severity b): +55°C/95%r.H., 6 cycles
Cold         -1  4.8.13    4.6.16     Test Aa: 2h at lower temp of climatic category
Climatic sequence         -7  4.8.14    4.6.17     Sequence of Dry heat, damp heat(1st cycle), Cold, Damp heat (5cycles)
Damp heat, steady state 202 103   40°C, 90-95%RH, 56 days -3  4.8.15    4.6.18     Test  Ca: 56 days
Temp. Cycle 883 1010 B  -55/+125°C Air,100 cycles, 10 min dwell              
Rapid Change of Temperature (Thermal Shock) 202
810
883
883
107
503
1010
1011,7



A



100°C to 0°C, water, 15 cycles
-14  4.8.5    4.6.5  4.8.45   Test  Na: 10 cycles at extremes of operating temp range, OCXO: -40°C/+85°C
*Disclaimer:
This table is a best effort approach. The author is not responsible and cannot guarantee for completeness, for accurate referencing, and for up-to-date data.


Diese Tabelle als .PDF-Datei herunterladen ? Download this table as .PDF file [11 kB] ?

Zum Ansehen und Herunterladen der PDF-Dateien benötigen Sie den Adobe Acrobat Reader.
For viewing and downloading of the PDF files you need an Adobe Acrobat Reader.
Get Acrobat Reader

Sollte es Ihnen gefallen, sagen Sie es ruhig in meinem Gästebuch ...
If you like it, tell me in my guestbook ...



Zurück zur Normen Hauptseite / Back to Standards main page