This page describes How_To repair the VRF preselector into the
Yeasu FT1000 mkV & Field models.
My rig is now 3 years old in jan.2005.
I had never supposed that such a class of equipment could suffer from that problem,
but as someone said "be never sure of any thing".
All of us "Hams" are playing ( well utilizing ) the rigs almost every day. Pressing the knobs is an easy task as eating biscuits.
But one day pressing the
VRF_ON\OFF key the received signals sounded not more so clear and loud.
The intensity of the signals was going up and down without
any QSB ... Uhmmm what was happening?
At once the
brain run in a sort of flow_chart list for a possible cable break from the antenna down to the rig,
but all the cabling were and are OK.
What and where the received signal could be interrupted in such a "strange" way was not clear at that moment.
So I
switched the rig OFF waited some seconds and re-ON, pressed again the VRF knob and all seemed ok.
OK go to listen again on the band for a possible qso. Had some contacts around and all seemed ok.
Then I played again the VRF switch to ON, all was OK.
Back to OFF and the signals disappeared with an up\down intensity.
Uhmmm...again...
The received signals were going up and down, but not due to a QSB.
At this time I was realizing that something inside the rig had gone wrong .
Remembering of the old days when a faulty contact could be cured by tapping on the case, specially the TV and Radio sets
with lot of tubes, I gently went to tap on the rig's chassis with the fingers, but nothing happened .
All the front switches had been turned and pushed, but nothing happened other than each own predefined function .
Then I
pressed the MOX button ( the VRF was OFF with almost all the received signal attenuated) just for couriosity and
because I guessed that the TX knobs had nothing to do with a faulty RX_signal_chain.
At once the rx-signal came out again in its original strenght.... Uhmmmm that was strange, but so it was.
And I recalled that in a TRX rig there are many circuits in common or switched IN&OUT from RX to TX and viceversa.
Every time I switched the VRF_Off the rx-signals disappeared and when I pressed the MOX the signals were back again.
The rx-signal attenuation with the VRF_Off disappeared
every time the rig was turned back from TX to RX.
That is why I have never noticed that fault before.
Having discovered the fault was not all. It had to be ensured which component caused the problem.
Studying the electric schematic was a first step.
Tracing the
received signal on the paper is quite simple.
Untill the rx-signals reach the
preselector there are no active components, only relays.
Therefore I supposed
that it should be a faulty relay (Rel1005) . It is the relay that switches the rx-signal into the VRF chain .
BUT :
How to ensure myself that was a faulty relay the cause of such incorrect reception?
EASY : open the rig , access to the RF_board, switch it ON and tap with a pen
on the board and the relays and see (better listen) what it happens.
Easy to say but harder to do. Because the part to check is well packed inside the FT1000mk_V_Field rig.
Follow this link for a step_by_step How_To access into the rig explanation
, for you will be easier than for me the first time.
Having the rig opened and secured that it can be switched ON without any error , you can try to "tap" around on the relays with a pencil.
IMPORTANT : tap very gently on the relays. I discovered almost soon that if the tap had been strong then also some other relay could move its
anker not only the one suspected to be faulty.
Repeat more times the tapping over the suspect relay to be sure that it is the faulty one.
Now you must decide only when to replace the relay. Follow the "Access into the Rig" procedure and change it.
Tools needed :
A screwdriver,a
small soldering iron (8/15 watt) or a regulated one, a desoldering pump, a magnifier glasses and of
course a couple of those famous TX2 relays as this one in the foto
But where could be purchased such Nais Matsushita TX2-12V relays ?
Most furnished electronic shops list this item.
I found it at a well known supplier in EU_lands: Conrad Electronics at www.conrad.de
Its part number is : Artikel-Nr.: 504788-14 SIGNALrelays TX 2U 2A 12V at 4,76 EUR for 1 piece. (still same price on feb2006)
and for the magnifier glasses I have choosen a head magnifier with interchangable lenses as this one:
KOPFBANDLUPE + SCHEINWERFER, VERSTELLBAR Artikel-Nr.: 812379-14 Preis 35,95 EUR
Third : how to remove such mini_relays ?
Well, once the faulty item is found it is not so much difficult to get it out of its place on the board.
taking the relay out
testing for the newone
showing the new soldering
The 3 fotos above show the few steps needed to do the change.
Sucking the tin from the relay pads is easy. Should be used a vacuum sucker care must be taken to the
board pads. The copper pads are not as strong as one may immagine.
The following picture shows how looks like the VRF circuitry on the RF board.
Reclosing the rig : be careful to route all the wires and cables away from the possible pinching of the screws.
Enjoy using your re-vitalized rig and use as les as possible the VRF tuning and bypass relays.
Should anyone use some other relay brand or do improvements please let me to know , to share the experiences with All.