Modifications for the Kenwood
TR-9250

19-07-1998 TR-9250 RF
LED Meter
The RF LEd meter may show reduced output after
continuous transmission, while output actually remains constant. Changing
components on the final unit will correct this problem. This change applies to
units before serial number 201XXXX.
Procedure:
- Remove the top cover (four screws), and unplug the speaker.
- Remove the bottom cover (four screws).
- Remove four scress holding the heatsink and swing the sink down.
- Without changing coil spacing, desolder L6 which connects from the ANT pad
aon the final unit to the PL-259, at the final unit.
- Remove five screws holding the final unit pcb X45-1180-10, one screw
holding Q6 2SD880, and two screws holding the final hybrid module Q1, M57726.
- Change the following parts:
C15 1pf to 2pf (CC45CH1H020C)
D3
1N60 to 1S1587 (V11-0370-05)
R8 820 ohm to 1.2K (RD14CD2E122J)
- Insure adequate thermal compound on Q1 and Q6, and that the mica washer is
correctly positioned under Q6. Reverse steps 5 and 4 to partially assemble.
- Cable-up power and a dummy load. Readjust VR1 on the final unit at 147.000
MHz, high power setting for 5 LED's ON. Switch to low power and verify 3 LEDs
ON.
- Remove power from the unit and complete reassebly by reversing steps 3, 2,
and 1.
Note installation time for this procedure is 1/2 hour or
less.